Phenominer Database Results (8 results)

 

Table "column sort" updates the order of the bars in the chart.
Strain Phenotype Conditions Study Experiment Name Sex Age # of Animals Value Units SEM SD Individual Records Method Method Duration Post Insult Time Value Experiment Notes Record ID Study ID
SS-Chr 3BN/Mcwi left ventricular developed pressure controlled air oxygen content (12 %) (for 14 days) then controlled oxygen content Kreb's solution perfusate (for 0.5 hours) PhysGen Cardiac data heart left ventricular blood pressure trait female 49.0 days-63.0 days 10 81.85 mmHg 6.08 19.23 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart Moms and pups used in studies were fed Teklad 48684 461
SS-Chr 3BN/Mcwi left ventricular developed pressure controlled air oxygen content (12 %) (for 14 days) then controlled oxygen content Kreb's solution perfusate (for 0.5 hours) PhysGen Cardiac data heart left ventricular blood pressure trait male 49.0 days-63.0 days 9 87.22 mmHg 4.06 12.19 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart Moms and pups used in studies were fed Teklad 48679 461
SS-Chr 3BN/Mcwi left ventricular developed pressure controlled oxygen content Kreb's solution perfusate (for 0.5 hours) PhysGen Cardiac data heart left ventricular blood pressure trait male 49.0 days-63.0 days 6 69.36 mmHg 5.56 13.63 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 46806 461
SS-Chr 3BN/Mcwi left ventricular developed pressure controlled oxygen content Kreb's solution perfusate (for 0.5 hours) then perfusate suspended (for 0.4 hours) then controlled oxygen content Kreb's solution perfusate (for 0.7 hours) PhysGen Cardiac data heart left ventricular blood pressure trait male 49.0 days-63.0 days 6 25.93 mmHg 5.83 14.29 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart Moms and pups used in studies were fed Teklad 47967 461
SS-Chr 3BN/Mcwi left ventricular developed pressure controlled air oxygen content (12 %) (for 14 days) then controlled oxygen content Kreb's solution perfusate (for 0.5 hours) then perfusate suspended (for 0.4 hours) then controlled oxygen content Kreb's solution perfusate (for 0.7 hours) PhysGen Cardiac data heart left ventricular blood pressure trait female 49.0 days-63.0 days 10 30.01 mmHg 4.66 14.73 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart Moms and pups used in studies were fed Teklad 45330 461
SS-Chr 3BN/Mcwi left ventricular developed pressure controlled oxygen content Kreb's solution perfusate (for 0.5 hours) PhysGen Cardiac data heart left ventricular blood pressure trait female 49.0 days-63.0 days 9 88.06 mmHg 7.79 23.37 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 46811 461
SS-Chr 3BN/Mcwi left ventricular developed pressure controlled air oxygen content (12 %) (for 14 days) then controlled oxygen content Kreb's solution perfusate (for 0.5 hours) then perfusate suspended (for 0.4 hours) then controlled oxygen content Kreb's solution perfusate (for 0.7 hours) PhysGen Cardiac data heart left ventricular blood pressure trait male 49.0 days-63.0 days 9 22.73 mmHg 5.51 16.53 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart Moms and pups used in studies were fed Teklad 45325 461
SS-Chr 3BN/Mcwi left ventricular developed pressure controlled oxygen content Kreb's solution perfusate (for 0.5 hours) then perfusate suspended (for 0.4 hours) then controlled oxygen content Kreb's solution perfusate (for 0.7 hours) PhysGen Cardiac data heart left ventricular blood pressure trait female 49.0 days-63.0 days 9 27.83 mmHg 5.78 17.35 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart Moms and pups used in studies were fed Teklad 47972 461