Phenominer Database Results (11 results)

 

Table "column sort" updates the order of the bars in the chart.
Strain Phenotype Conditions Study Experiment Name Sex Age # of Animals Average Type Value Units SEM SD Method Method Site Method Duration Post Insult Time Value Method Notes Record ID Study ID
SHR systolic blood pressure control condition Aneas I, et al., Physiol Genomics. 2009 Mar 3;37(1):52-7. Epub 2009 Jan 6. arterial blood pressure trait male 99 days 23 continuous mean 188.0 mmHg 2.0 9.59 vascular indwelling catheter method femoral artery 1800 0 pressure transducer (P23Dd; Stathan, Hato Rey, Puerto Rico), amplifier (GPA-4 model 2; Stemtech, Wood Dale, IL), 10-bit analog-to- digital converter (DataQ Instruments, Akron, OH) 65347 306
SHR.BN-(D2Rat226-D2Rat294)/Jk systolic blood pressure controlled sodium content drinking water (1 %) (for 15 days) Aneas I, et al., Physiol Genomics. 2009 Mar 3;37(1):52-7. Epub 2009 Jan 6. arterial blood pressure trait male 99 days 22 continuous mean 177.6 mmHg 2.0 9.38 vascular indwelling catheter method femoral artery 1800 0 pressure transducer (P23Dd; Stathan, Hato Rey, Puerto Rico), amplifier (GPA-4 model 2; Stemtech, Wood Dale, IL), 10-bit analog-to- digital converter (DataQ Instruments, Akron, OH) 12751 306
SHR systolic blood pressure controlled sodium content drinking water (1 %) (for 15 days) Aneas I, et al., Physiol Genomics. 2009 Mar 3;37(1):52-7. Epub 2009 Jan 6. arterial blood pressure trait male 99 days 24 continuous mean 196.6 mmHg 3.2 15.68 vascular indwelling catheter method femoral artery 1800 0 pressure transducer (P23Dd; Stathan, Hato Rey, Puerto Rico), amplifier (GPA-4 model 2; Stemtech, Wood Dale, IL), 10-bit analog-to- digital converter (DataQ Instruments, Akron, OH) 12749 306
SHR.BN-(D16Rat87-D16Mgh1)/Jk systolic blood pressure control condition Aneas I, et al., Physiol Genomics. 2009 Mar 3;37(1):52-7. Epub 2009 Jan 6. arterial blood pressure trait male 99 days 22 continuous mean 181.0 mmHg 2.0 9.38 vascular indwelling catheter method femoral artery 1800 0 pressure transducer (P23Dd; Stathan, Hato Rey, Puerto Rico), amplifier (GPA-4 model 2; Stemtech, Wood Dale, IL), 10-bit analog-to- digital converter (DataQ Instruments, Akron, OH) 65411 306
SHR.BN-(D16Rat87-D16Mgh1)/Jk systolic blood pressure controlled sodium content drinking water (1 %) (for 15 days) Aneas I, et al., Physiol Genomics. 2009 Mar 3;37(1):52-7. Epub 2009 Jan 6. arterial blood pressure trait male 99 days 23 continuous mean 178.5 mmHg 2.7 12.95 vascular indwelling catheter method femoral artery 1800 0 pressure transducer (P23Dd; Stathan, Hato Rey, Puerto Rico), amplifier (GPA-4 model 2; Stemtech, Wood Dale, IL), 10-bit analog-to- digital converter (DataQ Instruments, Akron, OH) 12753 306
BN systolic blood pressure controlled sodium content drinking water (1 %) (for 15 days) Aneas I, et al., Physiol Genomics. 2009 Mar 3;37(1):52-7. Epub 2009 Jan 6. arterial blood pressure trait male 99 days 64 continuous mean 134.4 mmHg 8.7 69.6 vascular indwelling catheter method femoral artery 1800 0 pressure transducer (P23Dd; Stathan, Hato Rey, Puerto Rico), amplifier (GPA-4 model 2; Stemtech, Wood Dale, IL), 10-bit analog-to- digital converter (DataQ Instruments, Akron, OH) 65342 306
SHR.BN-(D2Rat114-D2Rat123)/Jk systolic blood pressure controlled sodium content drinking water (1 %) (for 15 days) Aneas I, et al., Physiol Genomics. 2009 Mar 3;37(1):52-7. Epub 2009 Jan 6. arterial blood pressure trait male 99 days 23 continuous mean 179.3 mmHg 3.5 16.79 vascular indwelling catheter method femoral artery 1800 0 pressure transducer (P23Dd; Stathan, Hato Rey, Puerto Rico), amplifier (GPA-4 model 2; Stemtech, Wood Dale, IL), 10-bit analog-to- digital converter (DataQ Instruments, Akron, OH) 12750 306
SHR.BN-(D2Rat114-D2Rat123)/Jk systolic blood pressure control condition Aneas I, et al., Physiol Genomics. 2009 Mar 3;37(1):52-7. Epub 2009 Jan 6. arterial blood pressure trait male 99 days 22 continuous mean 175.0 mmHg 2.0 9.38 vascular indwelling catheter method femoral artery 1800 0 pressure transducer (P23Dd; Stathan, Hato Rey, Puerto Rico), amplifier (GPA-4 model 2; Stemtech, Wood Dale, IL), 10-bit analog-to- digital converter (DataQ Instruments, Akron, OH) 65393 306
SHR.BN-(D4Rat33-D4Rat54)/Jk systolic blood pressure controlled sodium content drinking water (1 %) (for 15 days) Aneas I, et al., Physiol Genomics. 2009 Mar 3;37(1):52-7. Epub 2009 Jan 6. arterial blood pressure trait male 99 days 23 continuous mean 188.7 mmHg 2.4 11.51 vascular indwelling catheter method femoral artery 1800 0 pressure transducer (P23Dd; Stathan, Hato Rey, Puerto Rico), amplifier (GPA-4 model 2; Stemtech, Wood Dale, IL), 10-bit analog-to- digital converter (DataQ Instruments, Akron, OH) 12752 306
SHR.BN-(D2Rat226-D2Rat294)/Jk systolic blood pressure control condition Aneas I, et al., Physiol Genomics. 2009 Mar 3;37(1):52-7. Epub 2009 Jan 6. arterial blood pressure trait male 99 days 22 continuous mean 168.0 mmHg 2.0 9.38 vascular indwelling catheter method femoral artery 1800 0 pressure transducer (P23Dd; Stathan, Hato Rey, Puerto Rico), amplifier (GPA-4 model 2; Stemtech, Wood Dale, IL), 10-bit analog-to- digital converter (DataQ Instruments, Akron, OH) 65400 306
SHR.BN-(D4Rat33-D4Rat54)/Jk systolic blood pressure control condition Aneas I, et al., Physiol Genomics. 2009 Mar 3;37(1):52-7. Epub 2009 Jan 6. arterial blood pressure trait male 99 days 22 continuous mean 173.0 mmHg 2.0 9.38 vascular indwelling catheter method femoral artery 1800 0 pressure transducer (P23Dd; Stathan, Hato Rey, Puerto Rico), amplifier (GPA-4 model 2; Stemtech, Wood Dale, IL), 10-bit analog-to- digital converter (DataQ Instruments, Akron, OH) 65406 306