Phenominer Database Results (9 results)

 

How to display a graph
Strain Phenotype Conditions Study Experiment Name Sex Age # of Animals Value Units SEM SD Method Method Site Method Duration Post Insult Type Post Insult Time Value Post Insult Time Unit Clinical Measurement Notes Record ID Study ID
SHR.BN-(D6Rat40-D6Rat170)/Mco lesioned artery residual lumen area balloon angioplasty Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery integrity trait male 126 days-140 days 25 0.04 mm2 ex vivo light microscopy with digital image analysis iliac artery 0.0 balloon vascular injury 56 days the error is reported as +/- %CV = (standard deviation/mean) � 100 69322 1136
SHR.BN-(D6Rat40-D6Rat170)/Mco artery neointimal hyperplastic lesion area to total wall area ratio balloon angioplasty Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery integrity trait male 126 days-140 days 25 12.6 % ex vivo light microscopy with digital image analysis iliac artery 0.0 balloon vascular injury 56 days the error is reported as +/- %CV = (standard deviation/mean) � 100 69317 1136
SHR.BN-(D6Rat40-D6Rat170)/Mco artery tunica media area balloon angioplasty Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery morphology trait male 126 days-140 days 25 0.11 mm2 ex vivo light microscopy with digital image analysis iliac artery 0.0 balloon vascular injury 56 days the error is reported as +/- %CV = (standard deviation/mean) � 100 69320 1136
SHR.BN-(D6Rat40-D6Rat170)/Mco artery tunica media thickness control condition Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery morphology trait male 126 days-140 days 25 0.05 mm2 ex vivo light microscopy with digital image analysis iliac artery 0.0 0 the error is reported as +/- %CV = (standard deviation/mean) � 100 69331 1136
SHR.BN-(D6Rat40-D6Rat170)/Mco artery lumen area control condition Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery morphology trait male 126 days-140 days 25 0.5 mm2 ex vivo light microscopy with digital image analysis iliac artery 0.0 0 the error is reported as +/- %CV = (standard deviation/mean) � 100 69329 1136
SHR.BN-(D6Rat40-D6Rat170)/Mco artery neointimal hyperplastic lesion area balloon angioplasty Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery integrity trait male 126 days-140 days 25 0.02 mm2 ex vivo light microscopy with digital image analysis iliac artery 0.0 balloon vascular injury 56 days the error is reported as +/- %CV = (standard deviation/mean) � 100 69318 1136
SHR.BN-(D6Rat40-D6Rat170)/Mco artery lumen area balloon angioplasty Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery morphology trait male 126 days-140 days 25 0.45 mm2 ex vivo light microscopy with digital image analysis iliac artery 0.0 balloon vascular injury 56 days the error is reported as +/- %CV = (standard deviation/mean) � 100 69319 1136
SHR.BN-(D6Rat40-D6Rat170)/Mco artery tunica media thickness balloon angioplasty Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery morphology trait male 126 days-140 days 25 0.04 mm2 ex vivo light microscopy with digital image analysis iliac artery 0.0 balloon vascular injury 56 days the error is reported as +/- %CV = (standard deviation/mean) � 100 69321 1136
SHR.BN-(D6Rat40-D6Rat170)/Mco artery tunica media area control condition Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery morphology trait male 126 days-140 days 25 0.14 mm2 ex vivo light microscopy with digital image analysis iliac artery 0.0 0 the error is reported as +/- %CV = (standard deviation/mean) � 100 69330 1136