Phenominer Database Results (8 results)

 

Table "column sort" updates the order of the bars in the chart.
Strain Phenotype Conditions Study Experiment Name Sex Age # of Animals Value Units SEM SD Individual Records Method Method Duration Post Insult Time Value Experiment Notes Record ID Study ID
FHH-Chr 11BN/Mcwi left ventricular diastolic blood pressure controlled oxygen content Kreb's solution perfusate (for 0.5 hours) PhysGen Cardiac data heart left ventricular blood pressure trait female 49 days-63 days 10 5.3 mmHg 0.32 1.01 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 49251 461
FHH-Chr 11BN/Mcwi left ventricular diastolic blood pressure controlled oxygen content Kreb's solution perfusate (for 0.5 hours) PhysGen Cardiac data heart left ventricular blood pressure trait male 49 days-63 days 10 5.74 mmHg 0.19 0.62 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 49250 461
FHH-Chr 11BN/Mcwi left ventricular diastolic blood pressure controlled air oxygen content (12 %) (for 14 days) then controlled oxygen content Kreb's solution perfusate (for 0.5 hours) then perfusate suspended (for 0.4 hours) then controlled oxygen content Kreb's solution perfusate (for 0.7 hours) PhysGen Cardiac data heart left ventricular blood pressure trait male 49 days-63 days 10 61.33 mmHg 3.94 12.47 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 46489 461
FHH-Chr 11BN/Mcwi left ventricular diastolic blood pressure controlled air oxygen content (12 %) (for 14 days) then controlled oxygen content Kreb's solution perfusate (for 0.5 hours) PhysGen Cardiac data heart left ventricular blood pressure trait male 49 days-63 days 10 5.58 mmHg 0.23 0.73 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 47269 461
FHH-Chr 11BN/Mcwi left ventricular diastolic blood pressure controlled air oxygen content (12 %) (for 14 days) then controlled oxygen content Kreb's solution perfusate (for 0.5 hours) PhysGen Cardiac data heart left ventricular blood pressure trait female 49 days-63 days 6 5.36 mmHg 0.15 0.36 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 47270 461
FHH-Chr 11BN/Mcwi left ventricular diastolic blood pressure controlled oxygen content Kreb's solution perfusate (for 0.5 hours) then perfusate suspended (for 0.4 hours) then controlled oxygen content Kreb's solution perfusate (for 0.7 hours) PhysGen Cardiac data heart left ventricular blood pressure trait male 49 days-63 days 8 58.66 mmHg 7.59 21.47 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 47774 461
FHH-Chr 11BN/Mcwi left ventricular diastolic blood pressure controlled air oxygen content (12 %) (for 14 days) then controlled oxygen content Kreb's solution perfusate (for 0.5 hours) then perfusate suspended (for 0.4 hours) then controlled oxygen content Kreb's solution perfusate (for 0.7 hours) PhysGen Cardiac data heart left ventricular blood pressure trait female 49 days-63 days 6 54.86 mmHg 4.05 9.92 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 46490 461
FHH-Chr 11BN/Mcwi left ventricular diastolic blood pressure controlled oxygen content Kreb's solution perfusate (for 0.5 hours) then perfusate suspended (for 0.4 hours) then controlled oxygen content Kreb's solution perfusate (for 0.7 hours) PhysGen Cardiac data heart left ventricular blood pressure trait female 49 days-63 days 10 54.89 mmHg 3.55 11.24 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 47775 461