Phenominer Database Results (9 results)

 

How to display a graph
Strain Phenotype Conditions Study Experiment Name Sex Age # of Animals Value Units SEM SD Method Method Site Method Duration Post Insult Type Post Insult Time Value Post Insult Time Unit Clinical Measurement Notes Record ID Study ID
SHR.BN-(D3Rat159-D3Rat1)/Mco artery lumen area balloon angioplasty Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery morphology trait male 126 days-140 days 13 0.39 mm2 ex vivo light microscopy with digital image analysis iliac artery 0.0 balloon vascular injury 56 days the error is reported as +/- %CV = (standard deviation/mean) � 100 69313 1136
SHR.BN-(D3Rat159-D3Rat1)/Mco artery neointimal hyperplastic lesion area balloon angioplasty Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery integrity trait male 126 days-140 days 13 0.04 mm2 ex vivo light microscopy with digital image analysis iliac artery 0.0 balloon vascular injury 56 days the error is reported as +/- %CV = (standard deviation/mean) � 100 69312 1136
SHR.BN-(D3Rat159-D3Rat1)/Mco artery tunica media thickness balloon angioplasty Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery morphology trait male 126 days-140 days 13 0.04 mm2 ex vivo light microscopy with digital image analysis iliac artery 0.0 balloon vascular injury 56 days the error is reported as +/- %CV = (standard deviation/mean) � 100 69315 1136
SHR.BN-(D3Rat159-D3Rat1)/Mco lesioned artery residual lumen area balloon angioplasty Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery integrity trait male 126 days-140 days 13 0.35 mm2 ex vivo light microscopy with digital image analysis iliac artery 0.0 balloon vascular injury 56 days the error is reported as +/- %CV = (standard deviation/mean) � 100 69316 1136
SHR.BN-(D3Rat159-D3Rat1)/Mco artery lumen area control condition Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery morphology trait male 126 days-140 days 13 0.39 mm2 ex vivo light microscopy with digital image analysis iliac artery 0.0 0 the error is reported as +/- %CV = (standard deviation/mean) � 100 69326 1136
SHR.BN-(D3Rat159-D3Rat1)/Mco artery neointimal hyperplastic lesion area to total wall area ratio balloon angioplasty Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery integrity trait male 126 days-140 days 13 28.31 % ex vivo light microscopy with digital image analysis iliac artery 0.0 balloon vascular injury 56 days the error is reported as +/- %CV = (standard deviation/mean) � 100 69311 1136
SHR.BN-(D3Rat159-D3Rat1)/Mco artery tunica media area balloon angioplasty Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery morphology trait male 126 days-140 days 13 0.08 mm2 ex vivo light microscopy with digital image analysis iliac artery 0.0 balloon vascular injury 56 days the error is reported as +/- %CV = (standard deviation/mean) � 100 69314 1136
SHR.BN-(D3Rat159-D3Rat1)/Mco artery tunica media area control condition Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery morphology trait male 126 days-140 days 13 0.1 mm2 ex vivo light microscopy with digital image analysis iliac artery 0.0 0 the error is reported as +/- %CV = (standard deviation/mean) � 100 69327 1136
SHR.BN-(D3Rat159-D3Rat1)/Mco artery tunica media thickness control condition Nestor Kalinoski AL, et al., Hypertension. 2010 Feb;55(2):555-61. Epub 2009 Dec 21. iliac artery morphology trait male 126 days-140 days 13 0.04 mm2 ex vivo light microscopy with digital image analysis iliac artery 0.0 0 the error is reported as +/- %CV = (standard deviation/mean) � 100 69328 1136